When the heat-shrinkable casing is used as wire marking, the wire marking should be set on the wire before crimping, and then the crimping work should be carried out. Do not use the heat shrink tubing on the one-sidedness of the cord end Copper Tube Terminals. If a yellow cage terminal is used, the heat shrink tubing should be used at the place where the cable jacket is removed from the distance of 11mm. The insertion of wire marking shall be the insertion of marking data or English letters along the radial direction of wire. When marking the horizontal position, the data or English letters should be aligned (to the operator), and the data bits (the last bit) should be away from the cord end terminal, as shown in Figure 7 to Figure 8. The standard mark is symmetrical and clear, and the orientation is appropriate.
1, Cable Lugs are suitable for the connection of copper conductors (section 1.25-5.5mm2) in power cable with electronic equipmentPART NO | ITEM NO | WIRE RANGE | DIMENSIONS | |||||||
AWG/MCM | mm 2 | ΦE | ΦD | Φd | W | B | L | COLOR | ||
LY0020-0001 | NL1.25-3 | 22-16 | 0.25-1.65 | 3.7 | 4.0 | 1.7 | 5.5 | 10.4 | 17.3 | RED |
LY0020-0002 | NL1.25-3A | 3.2 | 4.0 | 1.7 | 5.5 | 10.4 | 17.3 | |||
LY0020-0003 | NL1.25-3M | 3.7 | 4.0 | 1.7 | 6.6 | 10.4 | 20.3 | |||
LY0020-0004 | NL1.25-4 | 4.3 | 4.0 | 1.7 | 8.0 | 10.4 | 21.8 | |||
LY0020-0005 | NL1.25-4M | 4.3 | 4.0 | 1.7 | 6.6 | 10.4 | 20.3 | |||
LY0020-0006 | NL1.25-5 | 5.3 | 4.0 | 1.7 | 8.0 | 10.4 | 21.8 | |||
LY0020-0007 | NL1.25-6 | 6.4 | 4.0 | 1.7 | 11.6 | 10.4 | 27.5 | |||
LY0020-0008 | NL1.25-8 | 8.4 | 4.0 | 1.7 | 11.6 | 10.4 | 27.5 | |||
LY0020-0009 | NL1.25-10 | 10.5 | 4.0 | 1.7 | 13.6 | 10.4 | 31.8 | |||
LY0020-0010 | NL2-3 | 16-14 | 1.04-2.63 | 3.7 | 4.6 | 2.3 | 8.5 | 10.4 | 22.3 | BLUE |
LY0020-0011 | NL2-3A | 3.2 | 4.6 | 2.3 | 8.5 | 10.4 | 22.3 | |||
LY0020-0012 | NL2-3M | 3.7 | 4.6 | 2.3 | 6.6 | 10.4 | 19.8 | |||
LY0020-0013 | NL2-4 | 4.3 | 4.6 | 2.3 | 8.5 | 10.4 | 22.3 | |||
LY0020-0014 | NL2-4M | 4.3 | 4.6 | 2.3 | 6.6 | 10.4 | 19.8 | |||
LY0020-0015 | NL2-5 | 5.3 | 4.6 | 2.3 | 9.5 | 10.4 | 22.3 | |||
LY0020-0016 | NL2-6 | 6.4 | 4.6 | 2.3 | 12.0 | 10.4 | 27.3 | |||
LY0020-0017 | NL2-8 | 8.4 | 4.6 | 2.3 | 12.0 | 10.4 | 27.3 | |||
LY0020-0018 | NL2-10 | 10.5 | 4.6 | 2.3 | 13.6 | 10.4 | 30.8 | |||
LY0020-0019 | NL3.5-4 | 12-10 | 2.63-4.60 | 4.3 | 5.6 | 3.2 | 9.5 | 13.3 | 26.3 | YELLOW |
LY0020-0020 | NL3.5-5 | 5.3 | 5.6 | 3.2 | 9.5 | 13.3 | 26.3 | |||
LY0020-0021 | NL3.5-6 | 6.4 | 5.6 | 3.2 | 12.0 | 13.3 | 27.7 | |||
LY0020-0022 | NL3.5-8 | 8.4 | 5.6 | 3.2 | 12.0 | 13.3 | 27.7 | |||
LY0020-0023 | NL5.5-3 | 12-10 | 4.60-6.64 | 3.7 | 6.6 | 3.5 | 9.5 | 13.5 | 26.5 | YELLOW |
LY0020-0024 | NL5.5-4 | 4.3 | 6.6 | 3.5 | 9.5 | 13.5 | 26.5 | |||
LY0020-0025 | NL5.5-5 | 5.3 | 6.6 | 3.5 | 9.5 | 13.5 | 26.5 | |||
LY0020-0026 | NL5.5-6 | 6.4 | 6.6 | 3.5 | 12.0 | 13.5 | 32.5 | |||
LY0020-0027 | NL5.5-6S | 6.4 | 6.6 | 3.5 | 12.0 | 13.5 | 29.2 | |||
LY0020-0028 | NL5.5-8 | 8.4 | 6.6 | 3.5 | 15.0 | 13.5 | 34.5 | |||
LY0020-0029 | NL5.5-10 | 10.5 | 6.6 | 3.5 | 15.0 | 13.5 | 34.5 | |||
LY0020-0030 | NL8-3 | 8 | 6.64-10.52 | 3.7 | 8.3 | 4.5 | 10.0 | 17.5 | 30.0 | RED |
LY0020-0031 | NL8-4 | 4.3 | 8.3 | 4.5 | 10.0 | 17.5 | 30.0 | |||
LY0020-0032 | NL8-5 | 5.3 | 8.3 | 4.5 | 10.0 | 17.5 | 30.0 | |||
LY0020-0033 | NL8-6 | 6.4 | 8.3 | 4.5 | 11.0 | 17.5 | 31.5 | |||
LY0020-0034 | NL8-8 | 8.4 | 8.3 | 4.5 | 14.0 | 17.5 | 36.0 | |||
LY0020-0035 | NL8-10 | 10.5 | 8.3 | 4.5 | 18.0 | 17.5 | 39.5 |
Product Categories : Connecting Terminals > Plug-in Connecting Terminals